Leverandør af induktionsvarmerens kondensator

Hjem / Produkter
Jiand Antai Power Condensator Co., Ltd.
Jiand Antai Power Condensator Co., Ltd.
Jiande Antai Power Capacitor Co., Ltd. ja Kinas tilpassede producent af højeffektkondensatorer og Leverandør af induktionsvarmerens kondensator, Zhejiang Jiande Huaneng Capacitor Co., Ltd. er beliggende i Jiande City, Zhejiang-provinsen, på den smukke bred af Xin'an-floden. Virksomheden blev grundlagt i 2003 og har en historie på næsten 20 år. Virksomheden er specialiseret i produktion af RFM-serien af elektriske varmekondensatorer, små højfrekvente serieresonanskondensatorer og DZMJ-serien af DC-filterkondensatorer. Den har et komplet produktions- og kvalitetsstyringssystem og har bestået ISO9001-styringssystemcertificering og CE-certificering. Virksomheden har stærk teknisk styrke, avanceret produktionsteknologi, komplette testmetoder og uafhængige forsknings- og udviklingskapaciteter. Virksomhedens produkter er innovative i design, velfremstillede og af stabil kvalitet og nyder stor tillid fra brugere i ind- og udland. Med mere end 10 års eksporterfaring eksporteres dens produkter til USA, Italien, Tyskland, Ukraine, Tyrkiet, Sydkorea, Indien og andre lande. Serieresonanskondensatorer, højspændingskondensatorer med stor kapacitet og filterkondensatorer har fordele på de indenlandske og udenlandske markeder. Vi leverer... Højeffektkondensatorer sælge.
Æresbevis
  • Certificering
  • En dobbelt kølekondensator med integreret effektledning og varmeafledningsmekanisme
  • En slags svejsnings- og flippeplatform til kondensatorkølingsmekanisme
  • En kobberrørudvidelse og bøjningsanordning til varmeafledningsmekanisme til kondensatorer
  • En ekspansionsmaskine med kobberrør med en varmeafledningsmekanisme til kondensatorer
Nyheder
Professionelle tjenester Livskvalitet
  • 01
    Tilpassede tjenester

    Vi har et stærkt F & U -team, og vi kan udvikle og fremstille produkter i henhold til de tegninger eller prøver, som kunderne tilbød.

  • 02
    Koste

    Vi har to af vores egne casting -støberier og en CNC -bearbejdningsfabrik. Så vi kan tilbyde prisen og produkterne direkte.

  • 03
    Kvalitet

    Vi har vores eget testlaboratorium og avanceret og komplet inspektionsudstyr, som kan sikre kvaliteten af produkterne.

  • 04
    Kapacitet

    Vores årlige output overstiger 20.000 stykker, som kan imødekomme behovene hos kunder med forskellige indkøbsmængder.

  • 05
    Service

    Vi fokuserer på at udvikle produkter af høj kvalitet til top-end markeder. Vores produkter er i tråd med internationale standarder og eksporteres hovedsageligt til Europa, Amerika, Japan og andre destinationer over hele verden.

Jiand Antai Power Condensator Co., Ltd.
Servicegaranti

Virksomheden kan prale af et professionelt eftersalgsserviceteam med højt kvalificerede medarbejdere, omfattende teknisk erfaring og avanceret testudstyr. Virksomheden følger et videnskabeligt perspektiv på udvikling og har et tæt samarbejde med brugerne, engagerer sig i tæt teknisk udveksling og leverer "en-til-en" skræddersyede produktionstjenester. Virksomheden forfølger personlige og differentierede produkter og transformerer sin fremstillingsindustri fra en produktionsorienteret til en serviceorienteret. Gennem en evalueringsmekanisme for produktbrug fremmer virksomheden brugertilfredshedsprojekter og stræber efter at opnå nul brugerklager efter salg.

Jiand Antai Power Condensator Co., Ltd.
Produkter Branchekendskab

What is the design principle of the cooling channel for water-cooled induction heater tank capacitors?

Heat exchange principle: Water-cooled induction heater tank capacitors generate a lot of heat when working. The design of the cooling channel is based on the principle of heat exchange. By allowing cooling water to flow in the channel, the heat generated by the capacitor is absorbed, thereby reducing the temperature of the capacitor. Jiande Antai Power Capacitor Co., Ltd. has 40 years of professional experience. When designing cooling channels, it fully considers the efficiency of heat exchange to ensure that the product can operate stably under various working conditions. The induction heating melting capacitors and other products it produces have effectively solved the heat dissipation problem through reasonable cooling channel design, ensuring the excellent performance of the products, which is one of the reasons why its products have won wide recognition and trust from domestic and foreign customers.
Channel layout: The cooling channel is usually laid out around the heating element of the capacitor to achieve uniform heat dissipation. Common layout methods include spiral and parallel. The spiral channel enables the cooling water to flow in a spiral shape around the capacitor shell, increasing the contact area and contact time between the cooling water and the capacitor, and improving the heat exchange efficiency. The parallel channel is easy to process and install, and can ensure that the cooling water is evenly distributed in a certain area.
Channel size: The size of the cooling channel has an important influence on the cooling effect. If the channel diameter is too large, the cooling water flow rate is large, but the flow rate is low, and the heat exchange efficiency may not be high; if the channel diameter is too small, the flow rate is high, but the water resistance increases, which may lead to an increase in the power of the water pump and easy blockage. Generally speaking, the channel size needs to be determined based on factors such as the heat generation of the capacitor, the flow rate and pressure of the cooling water. During the production process, Jiande Antai Power Capacitor Co., Ltd. will use its own testing laboratory and advanced and complete testing equipment to test cooling channels of different sizes to find the best design solution to ensure product quality.

How to ensure the uniform flow of cooling water in the channel to achieve efficient heat dissipation and reduce the operating temperature of the capacitor?

Optimize the channel inlet design: In order to make the cooling water enter the cooling channel evenly, the design of the inlet is crucial. A diffusion-type inlet can be used to allow the water flow to be evenly dispersed when entering the channel to avoid the situation where the local flow rate is too high or too low. At the same time, a guide plate or diverter is set at the inlet to guide the water flow to each branch channel to ensure the uniform distribution of the water flow.
Adopt reasonable channel shape and structure: The shape and structure of the channel will affect the flow characteristics of the water flow. For example, the use of smooth inner walls can reduce the resistance of the water flow and avoid turbulence or vortexes in the water flow. In addition, setting appropriate spoiler elements in the channel, such as ribs or protrusions, can increase the disturbance of the water flow and improve the heat exchange efficiency, but at the same time, care should be taken to avoid uneven water flow caused by spoiler elements. When designing cooling channels, the R&D team of Jiande Antai Power Capacitor Co., Ltd. will comprehensively consider the shape, structure and arrangement of spoiler elements of the channel to achieve the best cooling effect and water flow uniformity.
Balance channel resistance: In order to ensure that the cooling water flows evenly in each channel, it is necessary to balance the resistance of the channel. For longer or more curved channels, the cross-sectional area of ​​the channel can be appropriately increased to reduce the resistance; for shorter or straight channels, the cross-sectional area can be appropriately reduced to make the resistance of each channel roughly equal. This ensures that the flow distribution of cooling water in different channels is uniform.
Install flow control devices: Installing flow control devices such as flow control valves or flow meters in the cooling system can monitor and adjust the flow of cooling water in real time. By precisely controlling the cooling water flow rate of each channel according to the operating temperature and actual needs of the capacitor, uniform heat dissipation can be achieved.
Regular maintenance and cleaning: Scale, impurities, etc. may accumulate in the cooling channel, affecting the uniformity of the water flow and the heat exchange efficiency. Therefore, the cooling system needs to be maintained and cleaned regularly to keep the channel clean and unobstructed.